Question 1:Orientation device can't detector the soft tube

Solution:Stop the machine first, then hold up the corresponding tube holder by hand, push the tube to the Orientation press head.  When the cursor is focused On the black line, press On. Then point the cursor at the blank part of the tube and press Off.

Question 2:The push rod under the inside heating head does not lifting

Solution:Stop the machine and then pull the push rod by hand to see if it can be pulled up.

Then loosen the screw according .Check to see if you can pull the push rod.

If the push rod is crooked, a new push rod should be replaced in time.

Question 3:The tube tail is burst

Solution:Find the metal rod under the inside heating head, and first loosen the two screws of the disc, and then move the metal rod up by 2-3mm. Finally, tighten the two screws.

The tube sealing is not good and the tube tail was opened.

If the tube sealing effect is changed when in the actual production process, you have these three ways to adjust it.

1. Adjust the inner heating temperature and the outer heating temperature.

Note: Don’t adjust the heating temperature more than 180 degrees.

Don’t adjust the heating temperature more than 310 degrees

2. If the first way is still not good, you could adjust this black rotary knob. Pull out lightly this black rotary knob, then adjust the inside heating air volume. When you set the appropriate position, push in.

Note: turn right is add the air volume.

Turn left is reduce the air volume.

3. If the first way and second way is still not good, you could adjust this black rotary knob. Turn right or turn left to adjust the machine running speed.

Note: turn right is improve the machine running speed.

Turn left is reduce the machine running speed.

Don’t adjust the machine running speed more than 35.